Amplificatoare pentru celule LCM

Informaţii

Producători

Produse vizualizate

Convertor D-CAN

New product

Convertor D-CAN

Producator: LCM Systems

D-CAN Canbus Digital Strain Gauge to Data Converter

Cerere oferta

More details

Informații

D-CAN Canbus Digital Strain Gauge to Data Converter

Features :

  • Simple mounting using M2 screw
  • Connections via plated through holes
  • Low profile to fit in very small apertures
  • Baud rates to 230k
  • High speed to 500 Readings/Sec
  • ±15KV ESD protected
  • Real mV/V calibration
  • Noise Immunity 5x heavy industrial level
  • Diagnostics LED
  • Remote shunt calibration
  • Very high stability
  • Peak and trough recording
  • Programmable dynamic filter
  • Operating voltage (5.4 - 18Vdc)

The D-CAN is a high performance digital signal conditioner for the precision measurement of strain gauge based transducers., providing a CANBus output.

There are two product types available in the range; the DSC and DCELL. Both products offer a  high speed CAN output.
The DCELL PCB is designed to fit inside the majority of sensors, providing a 'digital' load cell with the benefit of very high stability and an RS485 output.

Including the D-CAN into load cell based product enables the building of very high accuracy load cells, using the built in linearization and temperature compensation facilities

For applications where it is not possible to fit the DCELL within the transducer, there is an in line housing available (Model ILE).

Specification :

Product

DLCH High Stability

DLCS Industrial Stability

 
DescriptionMinTypMaxMinTypMaxUnits
Bridge Excitation 4.5 5 5.25 4.5 5 5.25 VDC
Bridge Impedance 320 350 5000 320 350 5000 Ohms
Sensor Impedance (18v supply) 320 350 5000 320 350 5000 Ohms ∆
Sensor Impedance (12v supply) 120 350 5000 120 350 5000 Ohms ∆
Bridge Sensitivity -3   +3 -3   +3 mV/V
Offset Temperature Stability   1 4   5 10 ppm/°C
Gain Temperature Stability   3 5   30 50 ppm/°C
Offset Stability with time   0.002 0.008   0.0035 0.016 %FR
Gain Stability with time     30     300 ppm of FR/1st year
Non Linearity 0.0005 0.0025     0.0005 0.0025 %FR
Internal Resolution   16 Million 16 Million       Counts/Divisions
Resolution @ 1Hz (Noise Stable)   400,000 100,00       Counts/Divisions
Resolution @ 10Hz (Noise Stable)   120,000 40,000       Counts/Divisions
Resolution @ 100Hz (Noise Stable)   50,000 10,000       Counts/Divisions
Resolution @ 500Hz (Noise Stable)   18,000 5,000       Counts/Divisions

Optional

 MinTypMaxMinTypMaxUnits
Temp Measurement Resolution   0.1     0.1   °C
Temp Measurement Accuracy   1     1   °C
Notes: From original offset at any time Stability over 100 seconds ∆ Subject to supply voltage (see electrical specifications)

Electrical

 MinTypMaxMinTypMaxUnits
Power Supply Voltage 5.4 12 18 5.4 12 18 Vdc
Power Supply Noise/Ripple     100     100 mVac pk-pk
Supply Current (350R Bridge)   45 60   45 60 mA
Power@10V Supply (350R Bridge)   350     350   mW
Excitation System   4 wire     4 wire    

Communications

 MinTypMaxMinTypMaxUnits
CAN bit Rate 10K   1M 10K   1M Bits/second
Protocols CANopen, MANTRACAN

CE & Environmental

Storage temperature -40 to +85ºC
Operating temperature -40 to +85°C
Relative humidity 95% maximum non-condensing
Safety/Low Voltage Directive 73/23/EEC amended by 93/68/EEC
BS EN 61010-1:2001, IEC 1010-1-1990
EMC Directive 89/336/EECBasic Standard BS EN 61326:1998
EMC Emissions BS EN 55011:1998
EMC Immunity BS EN 61000-42:1995BS
EN 61000-4-3:2002
BS EN 61000-4-4:2004
BS EN 61000-4-11:2004
 
 
 

Recenzii

Nu sunt opinii ale clienților în acest moment.

Scrieţi o recenzie

Convertor D-CAN

Convertor D-CAN

Convertor D-CAN

Producator: LCM Systems

D-CAN Canbus Digital Strain Gauge to Data Converter

Cerere oferta

Descărcări