Convertor D-CAN
Convertor D-CAN
Producator: LCM Systems
D-CAN Canbus Digital Strain Gauge to Data Converter
D-CAN Canbus Digital Strain Gauge to Data Converter
Features :
- Simple mounting using M2 screw
- Connections via plated through holes
- Low profile to fit in very small apertures
- Baud rates to 230k
- High speed to 500 Readings/Sec
- ±15KV ESD protected
- Real mV/V calibration
- Noise Immunity 5x heavy industrial level
- Diagnostics LED
- Remote shunt calibration
- Very high stability
- Peak and trough recording
- Programmable dynamic filter
- Operating voltage (5.4 – 18Vdc)
The D-CAN is a high performance digital signal conditioner for the precision measurement of strain gauge based transducers., providing a CANBus output.
There are two product types available in the range; the DSC and DCELL. Both products offer a high speed CAN output.
The DCELL PCB is designed to fit inside the majority of sensors, providing a ‘digital’ load cell with the benefit of very high stability and an RS485 output.
Including the D-CAN into load cell based product enables the building of very high accuracy load cells, using the built in linearization and temperature compensation facilities
For applications where it is not possible to fit the DCELL within the transducer, there is an in line housing available (Model ILE).
Specification :
Product |
DLCH High Stability |
DLCS Industrial Stability |
|||||
| Description | Min | Typ | Max | Min | Typ | Max | Units |
| Bridge Excitation | 4.5 | 5 | 5.25 | 4.5 | 5 | 5.25 | VDC |
| Bridge Impedance | 320 | 350 | 5000 | 320 | 350 | 5000 | Ohms |
| Sensor Impedance (18v supply) | 320 | 350 | 5000 | 320 | 350 | 5000 | Ohms ∆ |
| Sensor Impedance (12v supply) | 120 | 350 | 5000 | 120 | 350 | 5000 | Ohms ∆ |
| Bridge Sensitivity | -3 | +3 | -3 | +3 | mV/V | ||
| Offset Temperature Stability | 1 | 4 | 5 | 10 | ppm/°C | ||
| Gain Temperature Stability | 3 | 5 | 30 | 50 | ppm/°C | ||
| Offset Stability with time | 0.002 | 0.008 | 0.0035 | 0.016 | %FR | ||
| Gain Stability with time | 30 | 300 | ppm of FR/1st year | ||||
| Non Linearity | 0.0005 | 0.0025 | 0.0005 | 0.0025 | %FR | ||
| Internal Resolution | 16 Million | 16 Million | Counts/Divisions | ||||
| Resolution @ 1Hz (Noise Stable) | 400,000 | 100,00 | Counts/Divisions | ||||
| Resolution @ 10Hz (Noise Stable) | 120,000 | 40,000 | Counts/Divisions | ||||
| Resolution @ 100Hz (Noise Stable) | 50,000 | 10,000 | Counts/Divisions | ||||
| Resolution @ 500Hz (Noise Stable) | 18,000 | 5,000 | Counts/Divisions | ||||
Optional |
|||||||
|---|---|---|---|---|---|---|---|
| Min | Typ | Max | Min | Typ | Max | Units | |
| Temp Measurement Resolution | 0.1 | 0.1 | °C | ||||
| Temp Measurement Accuracy | 1 | 1 | °C | ||||
| Notes: From original offset at any time Stability over 100 seconds ∆ Subject to supply voltage (see electrical specifications) | |||||||
Electrical |
|||||||
|---|---|---|---|---|---|---|---|
| Min | Typ | Max | Min | Typ | Max | Units | |
| Power Supply Voltage | 5.4 | 12 | 18 | 5.4 | 12 | 18 | Vdc |
| Power Supply Noise/Ripple | 100 | 100 | mVac pk-pk | ||||
| Supply Current (350R Bridge) | 45 | 60 | 45 | 60 | mA | ||
| Power@10V Supply (350R Bridge) | 350 | 350 | mW | ||||
| Excitation System | 4 wire | 4 wire | |||||
Communications |
|||||||
|---|---|---|---|---|---|---|---|
| Min | Typ | Max | Min | Typ | Max | Units | |
| CAN bit Rate | 10K | 1M | 10K | 1M | Bits/second | ||
| Protocols | CANopen, MANTRACAN | ||||||
CE & Environmental |
|
| Storage temperature | -40 to +85ºC |
| Operating temperature | -40 to +85°C |
| Relative humidity | 95% maximum non-condensing |
| Safety/Low Voltage Directive | 73/23/EEC amended by 93/68/EEC BS EN 61010-1:2001, IEC 1010-1-1990 |
| EMC Directive | 89/336/EECBasic Standard BS EN 61326:1998 |
| EMC Emissions | BS EN 55011:1998 |
| EMC Immunity | BS EN 61000-42:1995BS EN 61000-4-3:2002 BS EN 61000-4-4:2004 BS EN 61000-4-11:2004 |