Indicator Cantarire E-Belt.

Indicator Cantarire E-Belt,  software pentru 3590E / indicatori CPWE pentru gestionarea de doze continua pe  curea.

Producator:Dini Argeo.

Categorie:
Descriere

.

 DOSAGE FUNCTIONS
  • 2 selectable operation modes:
    – Instantaneous reading of the flow, in kg/h or t/h with displaying of the status of the system and of the dosed total.
    – Adjustment of the dosage hourly flow, in function of the pre-setted target, with PID algorithm.
  • Visualisation of the hourly flow graph and wide range of data displayed on the display.
  • Calibration of the flow reading function, for controlling the dosage performances.
  • Reading filter of the hourly flow with configurable incidence and speed depending on the system.
  • Programmable dosage target upon weight or upon time, with relative contact.
  • Programmable start dosage delay, for synchronisation of various E-BELT systems in the dosage of material mixtures.
  • Management of the slow flow with programmable activation threshold, for more precise dosages.
  • Management of the dosage total under way and general total of dosages, printable and clearable independently from each other.
  • Management of the automatic dosage from remote master or through Profibus DP or Modbus RTU protocol.
  • Printing of the dosage data and the total.
  • Completely programmable printouts, for compatibility with any ASCII printer manageable through the serial port.
 DATABASES
  • Database of 100 products with: 5 alphanumeric description, hourly flow target, weight dosage target and initial value analogue output.
  • Manual programming of the products or throught PC software (Dinitools).
 KEYBOARD FUNCTIONS
  • START / RESTART dosage, PAUSE / RESET cycle and emptying of the belt out of the cycle.
  • Quick switch of the hourly flow target and of the dosage target.
  • Quick introduction and selection of the dosage data.
 I/O FUNCTIONS
  • Activation cycle, START / RESTART dosage, PAUSE / RESET cycle and unloading of the belt out of the cycle, through external inputs.
  • Impulse counter of the accumulated quantity through relay contact, for direct communication with PLC or external devices.
  • Relay contacts dedicated for the complete management of the alarms and the blocks for off weight, off flow and belt side-slipping.
  • Input and output with programmable functions.
  • 16 bit analogue input (optional) for programming the hourly flow target.
  • 16 bit analogue output (optional) proportional to the hourly flow (lector mode) or programamble for regulating the dosage speed (regulator mode).
  • Serial communication protocol for programming the products and reading the cycle status.
  • SYSWAY and MODBUS communication protocol for programming the dosage data and managing the cycle.

  • External Profibus interface (optional), for programming the dosage data and managing the cycle.

  • Optional Bluetooth connection, for quick wireless programming of the product, through PC or PDA.
Available versions

  Code Description  
BELT Software for reading/regulation of the flow on the weighing belt.

.