Etichete
Produse vizualizate
Indicator-controler 16 trepte de...
New product
Indicator-controler 16 trepte de reglaj ADP15-SP16
Producator: LCM Systems
This product is no longer in stock
Availability date:
Indicator-controler 16 trepte de reglaj ADP15-SP16
Indicator-controler 16 trepte de reglaj ADP15-SP16
Producator: LCM Systems
Destinatar(i) :
* Câmpuri obligatorii
sau Anulează
Features :
The DIN rail mounted remote relay units offer an increased number of set points over that provided by a standard ADP15 indicator/controller. This allows for multi action operations.
The software of the ADP-SP16 gives the user freedom to program the number of set points for their requirements. A single ADP-SP16 will control up to 16 set points, programmed from its front panel. Set points can be individually set up with In Flight compensation and hysteresis values. Separate 'Output Latch' and 'Output Action' for up to 14 of the 16 set points is available, settable from the front panel of the ADP-SP16. A special mnemonic allows the user to specify the number of set points to be used.
A DIN rail mounted power supply unit is required where more than 4 set points are to be used. The units are driven from the ADP-SP16 via an internal special remote driver board. All relays are pluggable and connections are made via field screw terminals.
Outputs include:-
Analogue voltage and current, Industry standard digital communications, Relays, Printer Drive
Options and Accessories include:-
Panel mounting via DIN rail mounting, Power supplies for 110/230 V AC or 9-32V DC, Communications for Printer, PLC or PC.
Software Options include:- Power Factor Printers DP data only and TDP for real time/date. Printers DP data only and TDP for real time/date.
Specification :
Input Type |
Details |
Calibration | Automatic digital by use of keypad and 1 (or 2) known weights. Manual calibration can also be selected |
Auto Tare | By pressing keys b and then 'R' , display will zero. Auto tare value can also be viewed and manually changed if required. Auto tare value is retained on power down. |
Sensitivity | Preset via DIL switches between ±0.5 to ±200mV/V |
Excitation | 10V DC nominal, 150mA maximum |
Compensation | By ± sense wires to compensate for cable, connection volt drops and any variation in 10V supply |
Accuracy | 90 days ± 0.08% of reading ± 0.05% of FS typical |
Drift | 0.002%ºC typical @ 2.5mV/V |
DC Analogue Outputs |
Details |
Order code |
0 to 10V | V4 | |
4-20mA | A3 | |
Other Information |
|
Accuracy | Typical ± 0.08% of output, ± 0.08%FSD |
Resolution | As display resolution, max 15 bits |
Calibration | By 15-turn pre sets for gain and offset |
Inversion | By keypad value |
Isolation | ±130V RMS or DC max to analogue input or to any other port |
Ranging | Fully keypad scalable over desired display range |
Communications Port |
Details |
Order code |
RS485/232 | RS485 - For up to 32 instruments on 1 bus, 4 wire RS232 printer or direct connection to 1 device, 3 wire |
COM 1 |
Other Information |
|
Baud rates | 300, 600, 1200, 2400, 4800, 9600 (19200 MANTRABUS only) |
Electrical isolation | ±130V RMS or DC max to analogue input or any other port |
Formats | MODBUS RTU, MANTRABUS and printer output formats |
Cable Length | 1km (depending on baud rate) |
Alarm/Control Outputs |
Details |
Order code |
SPCO | 4 relay module | REM4 |
SPCO | 8 relay module (PSU required) | REM8 |
PSU | Power supply for REM8 module | REMPSU |
REM cable | REM to REM cable (req. for additional REM units) | REMC2 |
Other Information |
|
Relays | 230V at 5A AC resistive |
Isolation | ±130V RMS |
Keypad Programmable | Hysteresis, Latching, Output Inversion. |
Power Supplies |
Details |
Order code |
240 | 220V-230V AC 50-60Hz 10W | 240 |
110 | 110V-120V AC 50-60Hz 10W | 110 |
12 &24V | 9-32V DC 10W isolated | 12/24 |
Mounting Type |
Order code |
Front Panel | P |
Din Rail Adaptor | D |
Communication Port CP Operation |
All display data can be accessed via the communications port along with relay and EEPROM status. All user configurable data can be changed including EEPROM enable/disable and relay reset (address code cannot be changed). |
Other Options & Accessories |
20mA PC Communications Interface (IF25) |
VisualLink PC SCADA Software |
Analogue Totaliser (Integrator) |
Base ADW15 |
|
Input Filter | Programmable to average up to 64 display updates. |
Displays | 7 segment LED 4.5 digit 10mm.3 x 3mm LED's 2 for relay status, 1 for program and hold indication. |
Update | Rate Up to 10 updates per seconds |
Controls |
|
4 membrane panel keys | Scroll key to view/update parameter. |
Digit select key. | |
Digit increment key. | |
Reset key. | |
Keypad disable by internal links behind front panel. | |
Hold function by digit select key when in input mode. |
Data Retention/Protection |
|
Retention | 10 years for set up values, minimum of 100,000 write cycle |
Protection of data and function(s)Watchdog timer giving repeat auto resets. | |
Impending power detection and hold off. | |
Keypad security and time out. |
CE & Environmental |
|
Storage temperature | -20 to +70ºC |
Operating temperature | -10 to 50°C |
Relative humidity | 95% maximum non condensing |
Safety/Low Voltage Directive | 2006/95/EC |
EMC Directive | 2004/108/EC |
Physical |
|
Case Dimensions | DIN 72 x 72 x 163mm (excluding mounting terminal) |
Case Material | Grey Noryl, flame retardant |
Weight | 750 grams |
Terminals | 2.5mm, saddle field terminals |
Accessibility | All electronics removable through front panel leaving field wiring and case in situ. |
Nu sunt opinii ale clienților în acest moment.