Code | Description | ||
CPWETF | Indicator with BATCH1 software. IP68 stainless steel case, 25-key keypad, backlit graphic LCD display, control light, 8 inputs and 16 outputs, programmable. |
Code | Description | ||
AF01 | Software for totalization and formula weighing. | ||
AF02 | Software for pieces/quantity counting. | ||
AF03 | Software for weighbridges, input/output vehicle. | ||
AF04 | Software for statistical checking of prepackaged goods. | ||
AF05 | Software for price compunting and industrial labelling. | ||
AF09 | Software for dynamic and static axle weighing with 2 platforms. | ||
BATCH | Software for multicomponent dosage systems in loading and unloading. | ||
CHECK | Software for packages weighting on a conveyor belt functions. | ||
BELT | Software for reading/regulation of the flow on the weighing belt. | ||
LW | Software for continuous dosage exiting from silos, tanks, hoppers. |
Code | Description | ||
PWCORDUK | Power supply cord with BS1363 plug (UK plug). |
Code | Description | ||
3590E4CH | (S1) Built-in board for multiple quick scale connection. | ||
LCCBC | (S1) Cable for connection between platform and indicator, l=50cm. Female connector to be soldered. | ||
LCCB5C | (S1) LCCBC cable + 5m extension cable. | ||
LCCB10C | (S1) LCCBC cable + 10m extension cable. |
Code | Description | ||
KCEM | Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination to a Dini Argeo indicator. |
Code | Description | ||
USBC | (S2) Built-in USB port kit for data storing on USB key. Fitted with USB key for PC. | ||
USBK | Set of 5 USB keys for recording the weighs. | ||
SWM | WeiMonitor PC program for monitoring and recording weighs in real time, from one or more scales. |
Code | Description | ||
PR80 | (S2) Thermal printer with print cutter. | ||
LP542S | (S2) Direct termal labeller. | ||
LP542TT | (S2) Thermal transfer or direct termal labeller. Peel-off kit in option. | ||
LPRPK | (S1) Peel-off kit for LP542TT (installation by customer). | ||
SMTPLUSPRO | (S2) Thermal transfer or direct termal labeller. Peel-off kit in option. | ||
SMTRPK | (S2) Label peel-off and rewind kit for SMTPLUS labeller. | ||
RSCBLP | (S1) RS232 cable l=1,5m for LP542xx, SMTPLUS, PR80 printers. | ||
LX300PRO | (S2) Dot matrix impact printer. | ||
TM295 | (S2) Dot matrix impact printer. | ||
RSCBLX | (S1) RS232 cable l=1,5m for LX300, TM295 printers. | ||
PRNSERV | Custom-made ticket (up to 4 layouts). NET price. For OBTPR../OBMMC/OBMDP/TM295/LX300 printer. | ||
APRNSERV | Custom-made label (up to 4 layouts). NET price. For LP542S/SMTPLUS labellers. |
Code | Description | ||
RSCBUSBPG | (S1) USB PC/RS232 converter cable, l=1,5m, with PG9. USB/RJ45 connector. For the connection to weight indicators with IP65 and IP68 protection system. | ||
OBRF-2 | (S2) External 868 MHz radio module, cable l=3m. ABS IP65 protecting box, 3 m cable, power supply from weight indicator. Max. distance, in appropriate environmental and installation conditions: 70m indoors, 150m outdoors. 50 configurable channels. | ||
RS485OPTO | (S1) Built-in optoisolated RS485 interface (mounting, cable gland excluded). | ||
SETHDIN | External RS232/RS485/RS422 to Ethernet converter connectable to all Dini Argeo weight indicators via the serial port, with ABS case, ideal for mounting on Omega / DIN bar. | ||
PROFI232-1 | External RS232/RS485/PROFIBUS interface for DIN bar. Connectable to the indicators with Profibus protocol. | ||
BLTH | (S1) Built-in bluetooth interface. For wireless connection to the portable PC or PDA. Weighing app downloadable from Google Play. | ||
WIFITD | (S2) Built-in WI-FI interface. For wireless connection (through access point) to the company computer system. | ||
ETHD | (S2) Built-in Ethernet interface. Speed from 10 to 100 Mbps, TCP, UDP, IP, ARP, ICMP, Ethernet Mac protocols. | ||
USBMB | (S1) Built-in USB interface, for PC (cable gland excluded). Mounting as an alternative of the standard connector RJ. | ||
DAC16O | (S1) Built-in analog output, 0-4/20 mA, 0-10VdC (cable gland excluded). NOTE: For 3590, only with IOEXPB optional board. |
||
RS485C | (S1) Built-in RS485 interface (mounting and cable gland excluded). | ||
PG9M | 10 PG9 stainless steel cable gland set for weight indicators. |
Code | Description | ||
RSCBRJ | (S1) RS232/C serial cable - DB9/RJ45 - l=1,5m. | ||
RSCBRJ10M | (S1) RS232/C serial cable - DB9/RJ45 - l=10m. | ||
ETHCBRJ | (S1) Ethernet cable, l=1,5m. Made up of fairlead, for connection between indicator and PC network. | ||
USBCABMB | USB/miniUSB PC cable l=1m (for USBMB option). |
Code | Description | ||
DGT100R | (S2) Weight repeater with 100mm LED display. IP68 stainless steel case, 5-key keypad, air valve for regulating the humidity and the pressure. |
Code | Description | ||
DCATEXMB4 | Declaration of ATEX conformity of the whole, Ex II 2GD IIC T6 T125°C X system, with relative label of whole system, for weight indicator connected to Dini Argeo zener barriers, connected to mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). ATEX CONFORMITY DECLARATIONS will be supplied in English. | ||
KMB4 | Kit of 3 passive safety ATEX zener barriers in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in an hazardous area. Marking of the single barrier: ATEX II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Marking of the whole box with three Zener barriers: ATEX II 3G Ex nA II T4 IP65 (-20°C ≤ Ta ≤ +40°C). | ||
JB4QA | ABS IP67, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT). | ||
JB4QAI | Stainless steel IP66, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT). | ||
EXCB6 | Shielded, blue, 6x0,25mmq signal cable, for EX i whole. €/m |
Code | Description | ||
SCCDR2 | Bar code scanner (it needs a mini DIN cable). Compatible with UPC/EAN, Code 39, 39 Full ASCII, 128 and others. Reading depth: 3-6 cm (resolution 0.076 mm), 3-25 cm (resolution 0.3 mm). | ||
PCKBRD | QWERTY PC keyboard (it needs a mini DIN cable). | ||
KBCBCE | (S1) PC keyboard or barcode reader cable with MINI DIN connector. |
Code | Description | ||
TLR-1 | (S2) Radio frequency remote control and receiver. 433MHz, with 6 key, for use up to 50 m of distance, in appropriate environmental conditions. |
Code | Description | ||
3590EEP | (S2) Built-in protection card against electric discharges according to IEC 1000-4-5/D (IEC 801-5/D). |
.